Get in touch
Connection board AP402I, for 4 sockets Lemo | Anwit
Connection board AP402I, for 4 sockets Lemo | Anwit
Connection boards

Connection board AP402I, for 4 sockets Lemo

4 channel connection board for voltages (±1 V, ±10 V, ±60 V) and currents (±20 mA)
TEDS Transducer identification
Supply voltage for active transducers can be chosen by jumpers: +5V, +8V, +16V
Max. 1 A for external sensor supply
Electrical isolation typ. 500 V
Transducer connection: Lemo-FCG6 socket
Usable with amplifier type ML801B (up to 2 AP402i per ML801B)

Specification
Accessories
Number of inputs4
InputElectrical voltage, Electrical current
OutputNone
InterfaceTCP/IP
Accuracy class0.01
Degree of protectionIP20
Sample rate [S/s]4.8 kHz
Real-time capabilitiesNone
Product CodeDescription
3-3312.0126Cable plug 6 pin, Lemo
1-ML801B8 channel DC amplifier